Test Item | Test Condition | Requirements | 9.8× 18.3 | 9.8× 19.8 |
Impulse Test | Oil temperature 135 º C Ambient temperature 135± 6 º C Cycle rate 30~40/min | 225, 000 Cycle without failure | > 230, 000cycles | > 230, 000cycles |
Tensile Test | > 5337.9N | > 7000N | > 7000N | |
Low Temprature Flexbility | The hose shall be bent through 180 º C on 8 times OD mandrel after the temprature of -40± 3º C for 24h | Hose shall not fracture or show any cracks, break in the tube or cover. | OK | OK |
Adhension | At the speed of 25mm/min | 44.48N/Inch | 112N/Inch | 126N/Inch |
Bursting Strength | 13.8 Mpa× 2min; Pressure Rate: 172.5+/-69Mpa | > 41.4Mpa | 61Mpa | 62Mpa |
Ozone Resistance | In the proportion of 50 pphm± 5 ozone in the air by volume for 70~72h at the temprature of 40 º C± 3 º C | The cover show no cracking at 7× magnification. | OK | OK |
Volumetric Expansion | 0~8.9 Mpa for 30s | Type 1 3~8 CC/FT | 5.4 CC/FT | 6.0 CC/FT |
Length Change | 0~10.3 Mpa | Type 1 +2%~ -5% | +1% | +1% |